-40%

Spirometrics Flowmate LTE Spirometer 2500LTE New Older Unit

$ 131.47

Availability: 100 in stock
  • MPN: 2500LTE
  • Model: Flowmate LTE
  • Type: Desktop Spirometer
  • S/N: 00648
  • Intended Use/Discipline: Pulmonology
  • Condition: An older but new and with original packing Spirometrics 2500LTE Spirometer. Does not come with supplies which are still available. Great if you need replacement parts like the AC power unit or new Flow Sensor. Does not come with supplies to use as a spirometer, but they are still available and with them could be used as a desktop spirometer.
  • Modified Item: No
  • Country/Region of Manufacture: United States
  • Brand: Spirometrics
  • All returns accepted: ReturnsNotAccepted

    Description

    Flowmate LTE Spirometer
    p/n 2500LTE
    Spirometrics
    Old Demo Unit (New unit nev
    er sold, was just used for sales demonstrations and/or demos.)
    Unit is complete with operators manual and all items necessary to do PFT testing for spirometry.
    Great to use for spare parts if ever necessary or buy the disposables necessary to do testing to have an inexpensive easy to use Spirometer.
    Comes with wall outlet plug in AC adapter included.  Can be used as a portable device with six (6) 1.2 volt AA Ni-Cad batteries (not included but readily available).
    An older but new and with original packing Spirometrics 2500LTE Spirometer.  Does not come with supplies which are still available.  Great if you need replacement parts like the AC power unit or new Flow Sensor.  Does not come with supplies to use as a spirometer, but they are still available and with them could be used as a desktop spirometer.
    Features
    Recognized Leadership
    in flow spirometry takes form in the Flowmate III. Fast, accurate testing of pulmonary function is portable and affordable.
    FULL FUNCTION.
    Every one of today's spirometry tests can be performed with your Flowmate III.
    EXTENSIVE MEMORY.
    Flowmate III can store the test results for 5 Patients; an optional Memory Card can hold test results for 118 patients, allowing you to print results at your convenience. Most 8 1/2" X 11" printers are supported.
    EXTENDED LIFE.
    The Flowmate III delivers up to 4.5 hours of continuous portable performance from an overnight battery charge.
    CROSS-CONTAMINATION PROTECTION.
    An inline filter protects the Flowmate III circuit from interpatient contamination.
    PORTABLE & COMPACT DESIGN.
    Battery operated and molded from high impact UL-rated ABS plastic for lightweight design
    PREDICTED NORMALS.
    Composite, Knudson, Crapo (ITS), ECCS, HSU, LAM.
    CUSTOMIZATION.
    Allows user to change report formats, temperature, barometric pressure and printer drivers; lithium battery backup. Back pressure less than 1.5 cmH2O/L/S.
    Validation.
    Complies with ATS, NIOSH and OSHA standards.
    Contamination Control.
    Cross-contamination control via an external filter system.
    Features
    Recognized Leadership
    in flow spirometry takes form in the Flowmate III. Fast, accurate testing of pulmonary function is portable and affordable.
    FULL FUNCTION.
    Every one of today's spirometry tests can be performed with your Flowmate III.
    EXTENSIVE MEMORY.
    Flowmate III can store the test results for 5 Patients; an optional Memory Card can hold test results for 118 patients, allowing you to print results at your convenience. Most 8 1/2" X 11" printers are supported.
    EXTENDED LIFE.
    The Flowmate III delivers up to 4.5 hours of continuous portable performance from an overnight battery charge.
    CROSS-CONTAMINATION PROTECTION.
    An inline filter protects the Flowmate III circuit from interpatient contamination.
    PORTABLE & COMPACT DESIGN.
    Battery operated and molded from high impact UL-rated ABS plastic for lightweight design
    PREDICTED NORMALS.
    Composite, Knudson, Crapo (ITS), ECCS, HSU, LAM.
    CUSTOMIZATION.
    Allows user to change report formats, temperature, barometric pressure and printer drivers; lithium battery backup. Back pressure less than 1.5 cmH2O/L/S.
    Validation.
    Complies with ATS, NIOSH and OSHA standards.
    Contamination Control.
    Cross-contamination control via an external filter system.
    Specifications
    Dimensions
    Height
    2.5"
    Depth
    5.5"
    Width
    8.75"
    Weight
    Net Weight
    3 lbs 13 oz.
    Power Requirements
    Battery
    Six 1.2 volt AA Ni-Cad batteries
    AC Adapter
    AC adapter is UL 544 recognized 9 volts DC @ 1 amp. Power consumption is 200 milliamps in operation; batter recharge time is 12 hours.
    Environmental
    Temperature Operating Range
    50F to 104F (10C to 40C)
    Maximum Storage Temperature
    150F (68C)
    User Interface
    Display
    2 by 40 LCD Display
    Keypad
    20 key membrane switch keypad.
    Patient Data
    ID Number
    Up to 16 digits including periods (.), and slashes (/).
    Age
    1 to 99 years.
    Sex
    Male, Female.
    Race
    Caucasian, Black, Non-Caucasian, Asian.
    Height
    Up to three digits, in inches or centimeters.
    Weight
    Up to three digits (optional entry) customizable as lbs. or kgs.
    Smoke
    0 - 60 cigarettes per day.
    TEST MANEUVERS
    FVC
    Forced Vital Capacity
    MVV
    Maximum Voluntary Ventilation
    VC
    Vital Capacity (otherwise known as Slow VC)
    Challenge
    Methacholine Challenge
    INDICES CALCULATED
    FVC Maneuver
    FVC
    Forced Vital Capacity
    FEV
    1
    1 second Forced Vital Capacity
    FEV
    3
    * 3 second Forced Vital Capacity
    FEV
    1
    /FVC
    % FEV
    1
    Ratio
    FEF
    25-75%
    Mid Expiratory Flow Rate
    FEF
    75-85%
    * Late Expiratory Flow Rate
    FEF
    200-1200
    * Forced Expiratory Flow Rate between 200ml and 1200ml
    FEF
    50
    * Forced Expiratory Flow Rate at 50% of FVC
    PEF
    Peak Expiratory Flow
    FIVC
    * Forced Inspiratory Vital Capacity
    FIF
    50
    * Forced Inspiratory Flow at 50% of FVC
    FIF
    50
    /FEF
    50
    * Ratio of FEF
    50
    to FIF
    50
    PIF
    * Peak Inspiratory Flow
    COPD
    Risk Assessment
    Lung Age
    Lung Age Assessment based on FEV1
    NOTE: FEV timing is based on back extrapolation
    * these indices appear on the expanded reports
    MVV Maneuver
    MVV
    Volume
    Volume Expired per minute
    MVV Rate
    Breaths per minute
    VC Maneuver
    VC
    Vital Capacity
    ATI
    Air Trapping Index
    Challenge
    FVC
    Forced Vital Capacity
    FEV1
    1 second Forced Vital Capacity
    PD20
    Provocative Dose
    FLOW SENSOR
    Maximum Flow Rate
    +/- 16liters/second
    Accuracy
    +/- 3%
    Resolution
    12 bit A/D
    Sampling Rate
    150Hz
    Back Pressure
    1.1 cmH2O/L/S@ 14L/S
    BTPS calculated automatically - based on user input for environmental conditions.
    Temperature
    50F to 104F (10C to 40C)
    Barometric Pressure
    20 to 35 inches of mercury, 500 to 900 millimeters of mercury. Input values determines units automatically.
    BEST TEST DETERMINATIONS (pertains to FVC trials only)
    FVC
    Largest regardless of test
    FEV1
    Largest regardless of test
    Ratio
    Combination of Best FEV1/Best FVC
    Flow Rates
    Taken from the trace with the greatest sum of FVC and FEV1
    Patient Effort
    Requires clinician to evaluate acceptable or unacceptable patient effort. Discards tests the clinician deems as unacceptable.
    Variability
    Compares indices of current test with best test in memory. Displays and prints variability as %. Variability greater than 5% for the FVC and/or the FEV1 is regarded as poor reproducibility.
    Expiratory Time
    If forced expiratory time is less than 6 seconds, a "TEST TOO SHORT" message will be displayed.
    Extrapolated Volume
    If extrapolated volume is greater than 5% of the FVC, a "SLOW START" message will be displayed.
    Interpretations
    Obstruction, Restriction, or Ventilary disorder.
    INPUT/OUTPUT COMMUNICATION PORTS
    Graphic Output
    Printouts according to ATS scale specifications.
    Printer Results
    External printer with selectable print drivers within customization. Results printed on standard 8.5" x 11" paper. Standard DB-25 Female IBM PC pin out to standard Centronic connection.
    Patient Storage
    Internal minimum of 5 patients. External storage with optional memory card for an additional 118 patients (64 pin battery backup RAM Card compatible with PCMCIA 2.0 connection).
    FVC
    - 6 trials each patient
    MVV
    - 2 trials each patient
    VC
    - 6 trials each patient
    Test Numbering
    Numbers each patient trial that is acceptable consecutively regardless of the type of test for recall later.
    MODEL
    Flowmate LTE
    COMPLIES WITH ATS STANDARDS
    Yes
    POWER NEEDED, VAC (ENERGY)
    120
    DIMENSIONS (HXWXD), CM(IN) (ENERGY)
    22.2x 14 x 6.4 (8.75x 5.5 x 2.5)
    WEIGHT, kg (lb) (DISPLAY)
    2.7(6)
    Type (CONFIGURATION)
    Tabletop
    DATA PROCESSING
    Microprocessor
    User-added data (PLOTS)
    Patient data
    Procedures/params evaluated (PLOTS)
    FVC; FEV 1, 3; PEF FEF 25-75, FEF 75-85%; FEF 50; PIF; MVV rate; VC; ATI; FEF,50%/FIF50%; FEV 1/FVC; FIVC; FEF 0.2-1.2
    Btps correction (PLOTS)
    Automatic
    Actual, normal, % normal report (PLOTS)
    Yes
    Predictive equations (PLOTS)
    Knudson, ITS, Morris, Hsu, ECCS
    Respiratory status/ diagnosis
    User selectable
    SINGLE-USE PARTS (PLOTS)
    Mouthpiece, filter
    STERILIZATION PROCESS (PLOTS)
    Cold
    DISPLAYS (STAINING POSTS)
    16-digit LCD
    Interface protocols (DATA PROCESSING)
    Yes
    HARD-COPY REPORT (PLOTS)
    8.5x 11"
    PRINTER TYPE
    Parallel
    Strip chart (PLOTS)
    Yes
    Speed, mm/sec (MICROSCOPE)
    20
    PLOTS
    Flow-volume loop (PLOTS)
    Yes
    MEASURING UNIT (PLOTS)
    Pneumotach
    Volume range, l
    0
    Precision (WAVELENGTH, nm)
    ±3%
    Flow range, l/sec
    0
    Precision (WAVELENGTH, nm)
    ±3%
    BIDIRECTIONAL (US OUTPUT)
    Yes
    Flow resistance (PLOTS)
    1.2cm H2O @ 12 L/s
    CALIBRATION METHOD (SPECIFIC GRAVITY)
    1or 3 L syringe
    OTHER ATTRIBUTES (Interference compensation)
    Pre/post bronchodilator; incentive display; automatic calibration; auto best test; methacho- line challenge test; filter disk.